DHT11 Temperature Humidity Sensor

55.00 EGP

Compact DHT11 Temperature Humidity Sensor (sensor only) with 4‑pin package, single‑wire digital output, 3.5–5.5 V supply, ≥2 s sampling period, ±2 °C / ±5 %RH — ideal for breadboards, Arduino/ESP, and indoor monitoring.

حساس DHT11 Temperature Humidity Sensor (قطعة منفردة) بعلبة 4 أرجل وخط بيانات واحد، يعمل بجهد 3.5–5.5 ف، فترة عيّنة ≥ 2 ث، انحراف ±2 °م / ±5 %RH — مثالي للبردبورد والمشروعات التعليمية والمراقبة الداخلية.

SKU DHT11Sensor SKU SYS Xb2537 Availability In stock
Quantities are confirmed after reviewing your order. Orders are normally prepared and shipped within 3–5 business days. Online availability does not necessarily mean the product is currently available at the branch. تأكيد الكميات بيتم بعد مراجعة الأوردر، وتجهيز وشحن الطلب بيستغرق عادة من 3 إلى 5 أيام عمل. توافر المنتج على الموقع لا يعني بالضرورة توافره داخل الفرع، لذلك اعمل الأوردر مسبقًا لتأكيد الكمية وتجهيزه.
تحتاج مساعدة؟ تواصل معنا
Share
Fast shipping Delivery across Egypt
Flexible payment Cash and online options
Quantity confirmation Confirmed after order review
Technical support Help choosing compatible parts

Description

DHT11 Temperature Humidity Sensor

Meet the DHT11 Temperature Humidity Sensor — the classic, compact, 4‑pin digital component (sensor only, not a module) that measures ambient relative humidity and temperature with a simple single‑wire interface. It operates on 3.5–5.5 V, features a stable indoor performance profile, and fits directly into breadboards thanks to its 2.54 mm pin spacing. Whether you are building a quick prototype, a classroom demo, or a budget‑friendly IoT node, this sensor keeps wiring simple and results repeatable.

Breadboard‑ready pins: Standard 2.54 mm pitch and fixed orientation make wiring straightforward in tight spaces and quick labs.
🔌 Flexible supply: Works reliably from 3.5–5.5 V with very low average current, suitable for battery‑friendly data loggers.
⚙️ Single‑wire digital output: Transmits a 40‑bit frame (humidity, temperature, checksum) — no analog calibration or ADC channels required.
🌡️ Indoor‑range sensing: Temperature 0–50 °C and humidity 20–90 %RH for common room and enclosure monitoring.
🧪 Beginner‑friendly accuracy: ±2 °C temperature and ±5 %RH humidity are perfect for learning, dashboards, and non‑critical control.
🧱 Vented protective head: The blue slotted cap shields the sensing elements while allowing smooth airflow for responsive readings.
🧰 Strong ecosystem support: Works out of the box with popular microcontroller libraries and examples.
💡 Low‑power behavior: Sub‑milliamp average draw with brief peaks during conversions keeps your power budget lean.

Why choose this sensor

Simplicity first — one data pin, a pull‑up resistor, and you’re reading live climate values.
Cost‑effective — trusted entry point for room‑level monitoring and education kits.
Community‑proven — recipes and sketches are widely available for mainstream boards.


Pinout & Wiring

  • Pin 1 — VDD: 3.5–5.5 V.
  • Pin 2 — DATA: Single‑wire bidirectional line. Add a 4.7–10 kΩ pull‑up to VDD near the host MCU for clean edges.
  • Pin 3 — NC: Not connected — leave floating.
  • Pin 4 — GND: Common ground with the controller.

Wiring tips

✅ Keep the DATA wire short; long unshielded runs can degrade timing margins.
✅ If your MCU is 3.3 V and the sensor is powered at 5 V, use a level shifter or power the sensor at 3.3 V for logic safety.
✅ Place the pull‑up resistor physically close to the MCU pin to reduce ringing.


Communication & Timing (what your code expects)

The host begins with a start pulse, after which the sensor acknowledges and shifts out 40 bits MSB‑first in this order:

  • 8‑bit humidity integer
  • 8‑bit humidity decimal
  • 8‑bit temperature integer
  • 8‑bit temperature decimal
  • 8‑bit checksum (low 8 bits of the sum of the previous four bytes)

Each bit uses a fixed low time followed by a high period whose duration encodes 0 or 1. A practical sampling period is ≥ 2 seconds; reading faster can repeat older values or increase checksum errors.


Typical Performance & Limits

  • Temperature range: 0–50 °C; resolution: 1 °C; accuracy: ±2 °C.
  • Humidity range: 20–90 %RH; resolution: 1 %RH; accuracy: ±5 %RH.
  • Sampling period: ≥ 2 s (1 sample every 2–3 seconds is common in robust designs).
  • Response time: ~6–10 s for humidity steps under normal airflow.
  • Supply voltage: 3.5–5.5 V.
  • Current: ~0.3 mA average during conversion; very low standby current.
  • Operating environment: Indoor, non‑condensing humidity.

Tip: If you need negative temperatures, sub‑zero operation, or tighter accuracy, step up to alternatives like higher‑grade digital humidity sensors. For educational builds and room monitoring, DHT11 Temperature Humidity Sensor remains an excellent fit.


Integration Notes (Arduino / ESP / Raspberry Pi)

Arduino: Connect DATA to a digital GPIO (e.g., D2), add a 4.7–10 kΩ pull‑up to VCC, and include a well‑known DHT library. Poll no faster than every 2 seconds.

ESP8266 / ESP32: Power at 3.3 V; use any available digital pin; keep wires short and stable. If Wi‑Fi tasks are heavy, avoid reading during RF bursts to reduce jitter.

Raspberry Pi: Use a driver that honors microsecond timing. Ensure 3.3 V‑safe pull‑up on DATA and adequate delays between reads.

Troubleshooting

🔧 Checksum errors → Slow the polling rate, verify the pull‑up value, and shorten the cable.
🔧 Stale or fixed readings → Ensure proper start pulse width and the recommended delay between reads.
🔧 No response → Check ground reference, verify that DATA is not accidentally shorted to VDD, and confirm pin numbering.


Specifications

ParameterValue
ProductDHT11 Temperature Humidity Sensor (sensor only)
Package4‑pin through‑hole, vented blue cap
Pin pitch2.54 mm
Pinout1‑VDD, 2‑DATA, 3‑NC, 4‑GND
Supply voltage3.5–5.5 V
Current (typ.)~0.3 mA during measurement; very low standby
Humidity range20–90 %RH (non‑condensing)
Humidity accuracy±5 %RH
Humidity resolution1 %RH
Temperature range0–50 °C
Temperature accuracy±2 °C
Temperature resolution1 °C
Sampling period≥ 2 s
InterfaceSingle‑wire digital, 40‑bit frame
Response time (RH)~6–10 s
Dimensions (approx.)15.5 × 12 × 5.5 mm
Operating conditionIndoor environments only

Handling & Placement

✅ Mount the sensor where air can flow freely; avoid enclosing it in sealed or foam‑lined cavities.
✅ Keep it away from heaters, voltage regulators, and direct sunlight to avoid self‑heating bias.
✅ Avoid corrosive gases and condensing moisture; allow a short warm‑up after power‑up for stable readings.
✅ If you must mount in an enclosure, provide vent holes and a short air path to the outside.


In the Box

  • 1× DHT11 Temperature Humidity Sensor (4‑pin loose component)

DHT‑11, blue humidity sensor, single‑wire temp‑humidity sensor.


DHT11 Temperature Humidity Sensor

حسّاس DHT11 Temperature Humidity Sensor هو المكوّن الرقمي الكلاسيكي ذو أربع أرجل (القطعة نفسها وليست موديول) لقياس الرطوبة النسبية ودرجة الحرارة عبر خط بيانات واحد. يعمل بجهد 3.5–5.5 فولت، ويتميّز بأداء مستقر في البيئات الداخلية، مع توافق ممتاز مع المتحكّمات الشائعة وتركيب مباشر على البردبورد بفضل تباعد الأرجل 2.54 مم. إذا كنت تطوّر نموذجًا سريعًا، أو تبني مشروع مراقبة للغرف، أو تدرّس أساسيات الاستشعار، فهذا الحساس يمنحك نتائج موثوقة بأسلاك قليلة.

جاهز للبردبورد: مسافات 2.54 مم وترتيب أرجل ثابت يسهل التوصيل بسرعة وبدون التباس.
🔌 تغذية مرنة: يعمل من 3.5 إلى 5.5 فولت وبتيار منخفض جدًا، مناسب لتسجيل البيانات وأجهزة البطاريات.
⚙️ خرج رقمي بسلك واحد: يرسل إطارًا مكوّنًا من 40‑بت (رطوبة، حرارة، وتحقق جمع) بلا معايرة تماثلية أو ADC.
🌡️ مدى داخلي شائع: حرارة 0–50 °م ورطوبة 20–90 %RH لمراقبة الغرف والصناديق.
🧪 دقة مناسبة للتعلّم: ±2 °م للحرارة و±5 %RH للرطوبة مع خطوة 1، مثالية للوحة معلومات أو تحكّم بسيط.
🧱 غطاء مثقّب واقٍ: يسمح بمرور الهواء ويحمي العنصر الحساس من الصدمات.
🧰 دعم مكتبات واسع: يعمل بسلاسة مع المكتبات والأمثلة الشائعة لمتّحدات MCU.
💡 استهلاك منخفض: تيار وسطي صغير جدًا وقمم قصيرة أثناء القياس للحفاظ على الطاقة.

لماذا تختاره

بساطة التوصيل — سلك بيانات واحد ومقاومة سحب، وستحصل على قراءات فورية.
قيمة مقابل السعر — خيار موثوق للمراقبة الداخلية والدروس العملية.
منظومة جاهزة — شيفرات وأمثلة منتشرة لمعظم اللوحات.


الأرجل والتوصيل (القطعة، ليست موديول)

  • 1 — VDD: 3.5–5.5 ف.
  • 2 — DATA: خط بيانات ثنائي الاتجاه. أضِف مقاومة سحب 4.7–10 كΩ إلى VDD بالقرب من المتحكّم.
  • 3 — NC: غير موصول.
  • 4 — GND: أرضي مشترك.

نصائح توصيل

✅ قصّر سلك DATA قدر الإمكان؛ الأطوال الكبيرة غير المحمية قد تُضعف هوامش التوقيت.
✅ عند اختلاف المستويات المنطقية، استخدم مبدّل مستويات أو شغّل الحساس على 3.3 فولت إذا كان المتحكّم يعمل على هذا الجهد.
✅ ضع مقاومة السحب قرب طرف المتحكّم للحد من التذبذب.


الاتصال والتوقيت

يبدأ المتحكّم نبضة بدء، ثم يرسل الحساس إشارة جاهزية ويتبعها بإطار 40‑بت بالترتيب: رطوبة صحيحة، رطوبة عشرية، حرارة صحيحة، حرارة عشرية، Checksum. كل بت يحتوي فترة منخفضة ثابتة تليها فترة مرتفعة يختلف طولها لتمييز الصفر عن الواحد. فترة العيّنة الموصى بها ≥ 2 ثانية؛ القراءة بسرعة أعلى قد تُكرر بيانات سابقة أو تؤدي إلى أخطاء تحقق.


الأداء والحدود النموذجية

  • مدى الحرارة: 0–50 °م؛ الخطوة: 1 °م؛ الدقة: ±2 °م.
  • مدى الرطوبة: 20–90 %RH؛ الخطوة: 1 %RH؛ الدقة: ±5 %RH.
  • فترة العيّنة: ≥ 2 ث.
  • زمن الاستجابة: يقارب 6–10 ث لتغيّر الرطوبة في ظروف تهوية طبيعية.
  • جهد التغذية: 3.5–5.5 ف.
  • التيار: ~0.3 مA أثناء القياس؛ تيار انتظار منخفض جدًا.
  • بيئة التشغيل: داخلية بدون تكاثف.

تلميح: إذا كنت تحتاج درجات سالبة أو دقة أعلى، توجّه إلى خيارات بديلة أعلى درجة. لمشروعات التعليم والمراقبة العامة، يبقى DHT11 Temperature Humidity Sensor خيارًا عمليًا.


التكامل (Arduino / ESP / Raspberry Pi)

Arduino: DATA إلى GPIO رقمي (مثل D2)، مقاومة سحب 4.7–10 كΩ إلى VCC، استخدم مكتبة DHT شائعة، ولا تُحدّث أكثر من مرة كل ثانيتين.

ESP8266 / ESP32: تشغيل على 3.3 فولت؛ اختر أي دبوس رقمي؛ قلّل طول الأسلاك. راعِ المهلة بين القراءات خصوصًا أثناء نشاط الشبكة.

Raspberry Pi: استخدم برنامج تشغيل يلتزم بتوقيت الميكروثانية، وسحبًا لأعلى متوافقًا مع 3.3 فولت.

استكشاف الأخطاء

🔧 أخطاء Checksum → خفّض معدل القراءة، تحقّق من قيمة مقاومة السحب، وقصّر السلك.
🔧 قراءات ثابتة → تأكد من عرض نبضة البدء والمهلة بين الاستدعاءات.
🔧 لا توجد استجابة → افحص التوصيلات والأرضي وتوجيه الأرجل.


جدول المواصفات

البندالقيمة
المنتجDHT11 Temperature Humidity Sensor (القطعة فقط)
التغليف4 أرجل TH بغطاء أزرق مثقّب
تباعد الأرجل2.54 مم
ترتيب الأرجل1‑VDD، 2‑DATA، 3‑NC، 4‑GND
جهد التشغيل3.5–5.5 ف
التيار (نموذجي)~0.3 مA أثناء القياس؛ انتظار منخفض جدًا
مدى الرطوبة20–90 %RH (بدون تكاثف)
دقّة الرطوبة±5 %RH
خطوة الرطوبة1 %RH
مدى الحرارة0–50 °م
دقّة الحرارة±2 °م
خطوة الحرارة1 °م
فترة العيّنة≥ 2 ث
الواجهةسلك واحد رقمي، 40‑بت
زمن الاستجابة (رطوبة)~6–10 ث
الأبعاد (تقريبية)15.5 × 12 × 5.5 مم
بيئة التشغيلداخلية فقط

الإرشادات والتموضع

✅ ضع الحساس في مكان بتهوية جيدة بعيدًا عن مصادر الحرارة والضوء المباشر.
✅ تجنّب التعرض للغازات المسببة للتآكل أو الرطوبة المتكاثفة.
✅ اسمح بدقيقة أو دقيقتين بعد التشغيل لاستقرار القراءات.
✅ عند التركيب داخل صندوق، وفّر فتحات تهوية مناسبة.


محتويات العبوة

  • 1× حساس DHT11 Temperature Humidity Sensor (قطعة منفردة ذات أربع أرجل)

DHT‑11، حساس الرطوبة الأزرق، حساس حرارة‑رطوبة بسلك واحد.


Attachments


DHT22 / AM2302digital humidity sensorDHT‑11
AM2301 classsingle‑wire sensorblue humidity sensor
SHT30 / SHT31breadboard temperature sensortemp & humidity sensor
AHT10 / AHT20room climate sensor4‑pin humidity sensor
BME280 / SHTC3indoor comfort monitordigital temp‑humidity
DS18B20 (temp only)Arduino humiditysingle‑wire TH sensor

Related Products

Products With Similar Tags