Description
Overview 🔌
Single-secondary EI laminated step-down transformer converting 220–240 VAC mains to 9 VAC @ 2 A (≈18 VA). Suitable for linear PSUs, audio, hobby electronics, and general-purpose AC applications. This listing is for 9 VAC only (NOT 9‑0‑9). See Transformer – Wikipedia for background.
Key Features ⭐
- Primary: 220–240 VAC, 50/60 Hz (Egypt mains compatible)
- Secondary: 9 VAC (RMS), 2 A (isolated)
- Approx. power: 18 VA
- Open-frame EI laminated core
- Lead colors/terminal style may vary by batch (assumption; verify before wiring)
Detailed Specifications 📐
| Parameter | Value | Notes |
|---|
| Input (primary) | 220–240 VAC, 50/60 Hz | Live/Neutral only (no earth on primary terminals) |
| Output (secondary) | 9 VAC @ 2 A | Single secondary; not center-tapped |
| Power rating | ≈18 VA | Vrms × I |
| Regulation | Not specified | Typical EI 10–20% at full load (assumption) |
| Isolation | Galvanically isolated | Standard mains transformer construction |
| Insulation class | Not specified | Check batch/supplier if critical |
| Mounting | Chassis / base mount | Through-bolts or L‑brackets |
Pinout & Wiring 🧰
| Side | Terminals | Function |
|---|
| Primary | P1 – P2 | Connect 220–240 VAC (L/N) |
| Secondary | S1 – S2 | 9 VAC output (isolated) |
Performance & Calculations 📊
- Approx. DC after bridge + capacitor (no load):
VDC ≈ Vrms·√2 − 2·Vf → 9·1.414 − ~1.4 ≈ ≈11.3 V. - Ripple capacitor sizing (50 Hz mains, full-wave):
C ≈ I/(2·f·ΔV). Example for 2 A, ΔV=1 V: C ≈ 2/(2·50·1) = 20,000 µF. - Use appropriate bridge rectifier and fuse. See Rectifier – Wikipedia.
Applications ⚙️
Linear DC supplies (with bridge + filter), low‑voltage AC loads, small amplifiers, Arduino/MCU projects via regulator, sensors and relays (with rectification).
Installation & Safety 🔒
Mains safety required. Isolate primary, add primary fuse/thermal fuse, strain relief, and earth the metal chassis if used. Keep primary/secondary wiring separated. Follow local electrical codes.
Testing & Commissioning 🧪
- No‑load test: apply 220–240 VAC, verify ~9 VAC RMS at S1–S2.
- Load test: draw up to 2 A and confirm voltage within regulation.
- DC build: add bridge + bulk capacitor; verify VDC and ripple.
Attachments & Datasheets 📝
- ]Background: Transformer – Wikipedia: https://en.wikipedia.org/wiki/Transformer
Videos ▶️
Dimensions
Not specified by suppliers; verify physical size before final enclosure design.
نظرة عامة 🔌
محول EI خافض بملف ثانوي واحد يحوّل 220–240 فولت AC إلى 9 فولت AC عند 2 أمبير (≈18 VA). مناسب لمزودات الطاقة الخطية والتطبيقات العامة. الموديل ده 9 فولت فقط (مش 9‑0‑9).
المميزات ⭐
- المدخل: 220–240 فولت، 50/60 هرتز
- المخرج: 9 فولت AC (RMS) عند 2 أمبير
- قدرة تقريبية: 18 VA
- قلب صفائح نوع EI
- ألوان الأسلاك/أطراف التثبيت بتختلف حسب التشغيلة (افتراض—اتأكد قبل التوصيل)
المواصفات التفصيلية 📐
| البند | القيمة | ملاحظات |
|---|
| المدخل | 220–240 VAC | يوصل على L/N فقط |
| المخرج | 9 VAC عند 2 A | ثانوي مفرد |
| القدرة | ≈18 VA | Vrms × I |
| التنظيم | غير مذكور | عادة 10–20% عند الحمل الكامل (افتراض) |
| العزل | معزول جلفانيًا | ترانس تقليدي |
التوصيلات 🧰
| الجانب | الأطراف | الوصف |
|---|
| الابتدائي | P1 – P2 | دخول 220–240 VAC |
| الثانوي | S1 – S2 | 9 VAC |
الأداء والحسابات 📊
- تقريب جهد DC بعد القنطرة والمكثف:
VDC ≈ Vrms·√2 − 2·Vf ≈ 11.3 فولت (بدون حمل). - تقدير المكثف:
C ≈ I/(2·f·ΔV) → لحمل 2 A وتموج 1 فولت ≈ 20,000 µF.
الاستخدامات ⚙️
مزودات DC خطية، أحمال AC منخفضة الجهد، دوائر تحكم، صوتيات بسيطة، مشاريع أردوينو بعد التقويم والتنظيم.
التركيب والسلامة 🔒
اتبع اشتراطات السلامة مع الكهرباء العمومية، فيوز على الابتدائي، وعزل الأسلاك كويس.
الاختبار والتشغيل 🧪
قِس الجهد بدون حمل ثم تحت الحمل، وبعد التقويم راقب الجهد والتموج.